長(zhǎng)春市齊祥科技有限責(zé)任公司 |
地址:長(zhǎng)春市普陽(yáng)街1688號(hào) |
電話:0431-85889497 85889498 |
傳真:0431-85889498 |
手機(jī):13089110318 |
|
|
?
自動(dòng)沖床下死點(diǎn)監(jiān)視裝置RM2402/2404-理研計(jì)器 |
|
自動(dòng)沖床下死點(diǎn)監(jiān)視裝置
Automatic Press Bottom Dead Point Monitoring Device
NEW SELBER BX RM-2402、2404
RM2402的優(yōu)勢(shì):
1)RM2402的分辨率是0.5um,表示可以察覺(jué)極小的變化值。越是薄的材料,越需要高分辨率。正常的下死點(diǎn)變位差是監(jiān)視沖床下壓后的距離。軟性材料以及薄質(zhì)材料,如有跳屑、小雜物,在沖壓最后會(huì)被壓扁在一起,分辨度不夠高,或許無(wú)法察覺(jué)其差異。
2)RM2402多了一個(gè)功能選擇(第一彈跳變位差監(jiān)視模式),提前檢查接觸時(shí)距離差。當(dāng)材料,或是模具有異物時(shí),在接觸的時(shí)候,便可檢查出來(lái),可減少模具受損。同時(shí),防止生產(chǎn)出壓扁變形的不良產(chǎn)品。
3)對(duì)應(yīng)沖床最高轉(zhuǎn)速=4000min(spm)。
4)對(duì)應(yīng)沖床最小沖程高度=4mm。
5)該產(chǎn)品穩(wěn)定性良好,客戶抱怨極少。
簡(jiǎn)介:
It detects slugs coming up by measuring the bottom dead point position of stripper plate.
Since it will catch up with 4000 rpm as maximum, it is good for high speed precision press machine to detect slug coming up.
Characteristics
It covers as small as 4mm stroke length of a press machine. (It was 8mm for the conventional unit.) It has sensor compensation function.
Similar sensor s made by other makers are also applicable.
•It is miniaturized in a half size of the conventional unit (MB, MX 2sets).
•It enables high accuracy detection. Resolution : 0.5μm
•It has first bound detection function. (First bound automatic search function.)
•The brightness of display is about 4 times brighter than conventional unit. It keeps clear view from a distance.
•Error lamp will blink when error is detected.
•Maximum 4-channel detection is available by installing an additional option unit (RM-2502).
Detection Method
1. Bottom Dead Center Mode (B.D.C.)
If a slug is caught in the die with spring loaded stripper, the stripper position will be changed. The slug is detected by the displacement of the stripper at B.D.C.
2. 1st Bound Mode
When the die has extra high spring force or is of bottoming construction, the slug may be almost entirely crushed, thus it may be too difficult to detect the stripper displacement. In such a case, you can use 1st Bound Mode, where the sensor highlights the stripper displacement when the stripper touches the slug (before it is crushed).
Setting of Monitoring Value
BX unit detects the difference of B.D.C. data between the current and the receding shots as the deviation (B.D.C. displacement). Setting of monitoring value is setting of the allowable limit of displacement.
SPECIFICATIONS
Designation & Type | NEW SELBER BX RM-2402 | Sensor principle | Eddy current loss type | Proximity sensor | RS-833H | Displacement indication | +/- 99.5μm LED 3 digits(0.5μm/digit) | Monitor value indication | 99.5μm LED 3 digits(0.5μm/digit) | Repeatability | Less than 0.5μm | Output | Relay contact(NO, NC) 250V 2A 2 circuits Stop output(STOP OUT) Auxiliary output(AUX OUT) | Input | No-voltage contact input 3 inputs Rest input(RESET IN) Non-Monitor(Start) input(NON-MON.IN(START IN)) Cycle Non-Monitor input(CYCLE NON-MON.IN) | Reaction to abnormality | Indication lamp blinks and output the stop signal. (Response speed is less than 10msec.) | Circum. temperature | 0-50degrees | Max. SPM | 4000 min-1(spm) | Sensor setting distance | 1.2+/-0.4mm | Sensor Cable length | Proximity sensor 10cm Connection cable 3m | Dimensions | 120(W) X 90(H) X 140(D)mm (Excluding projections and fixing angles.) | Power source | AC100-230V | Power consumption | Less than 20VA | Optional unit | | Designation & Type | NEW SELBER AX RM-2502(Max. 2 units applicable) | Dimensions | 120(W) X 30(H) X 140(D)mm approx. (Excluding projections) | | For improvement of the products, the specifications may be changed without prior notice. | |
|
|
|
|
|